5.3 UDV Expansion
To expand UDV size, please follow the steps below.
1. Select “/Volume con g/User data volume”
2. Select the UDV to be expanded and click the “ ” button next to the number in the Size eld.
3.
Change the volume size. The volume size must be larger than the original value. Then click
” to start expansion
4. Expansion starts. If UDV needs initialization, it will display an “I” in “Status 3” eld and the progress
percentage “R%”
Remind : The volume of UDV expansion must be larger than original value
Note : UDV expansion cannot be executed during rebuilding or migration
5.4 Disk roaming
Physical disks can exchange to different slot in the same system or be completely moved from system 1
to system 2. This is called disk roaming. Disk roaming is restricted by the following conditions:
1. Check the rmware version of the two systems. It is recommended that both systems are using
the same rmware.
2. The VG included in whole physical disks should be moved together. The architectures of the VG
and UDV will be kept but LUN architecture will be cleared to avoid con ict with system 2.
5.5 Support Microsoft MPIO and MC/S
MPIO (Multi-Path Input/Output) and MC/S (Multiple Connections per Session) both use multiple physical
paths to create logical paths between the server and the storage device. Under regular use, in case
one or more connections fail, the transmission is supposed to stop. But multi-path users can adopt an
alternate path for I/O to make sure that the data access is still working.
Microsoft iSCSI initiator supports multi-path function, please follow the steps below to use the MPIO function.
1. A host with dual LAN ports is connected to Sans Digital iSCSI Series Products
2. Create a VG/UDV and attach this UDV to the host
3. When install “Microsoft iSCSI initiator”, install MPIO driver at the same time
4. Login to target separately on each port. When login to target, con rm “Enable multi-path”. Please
refer to step 6 in Appendix D
5. MPIO mode can be selected by Targets Æ Details Æ Devices Æ Advanced
6. Rescan the disk
7. There will be one disk running MPIO
For detailed con gure steps, please refer to Appendix E: MPIO and MC/S Con gure Instructions. The
con gure steps for MC/S are very similar to that for MPIO, please refer to Appendix E.
52 RAID Introduction