- 62 -
INFO VD scrubbing started VD <name> starts scrubbing.
INFO VD scrubbing
finished
VD <name> completes scrubbing.
INFO RG migration started RG <name> starts migration.
INFO RG migration finished
RG <name> completes migration.
INFO RG activated RG <name> has been manually activated.
INFO RG deactivated RG <name> has been manually deactivated.
INFO VD rewrite started Rewrite at LBA <address> of VD %s starts.
INFO VD rewrite finished Rewrite at LBA <address> of VD %s completes.
WARNING VD rewrite failed Rewrite at LBA <address> of VD %s failed.
WARNING RG degraded RG <name> is under degraded mode.
WARNING VD degraded VD <name> is under degraded mode.
ERROR RG failed RG <name> is failed.
ERROR VD failed VD <name> is failed.
WARNING Recoverable read
error occurred
Recoverable read error occurred at LBA
<address>-<address> of VD <name>.
WARNING Recoverable write
error occurred
Recoverable write error occurred at LBA
<address>-<address> of VD <name>.
ERROR Unrecoverable read
error occurred
Unrecoverable read error occurred at LBA
<address>-<address> of VD <name>.
ERROR Unrecoverable write
error occurred
Unrecoverable write error occurred at LBA
<address>-<address> of VD <name>.
INFO Dedicated spare
configured
PD <slot> has been configured to RG <name> as a
dedicated spare disk.
INFO Global spare
configured
PD <slot> has been configured as a global spare
disk.
WARNING PD read error
occurred
Read error occurred at LBA <address>-<address>
of PD <slot>.
WARNING PD write error
occurred
Write error occurred at LBA <address>-
<address> of PD <slot>.
WARNING Parity wrong when
scrubbing
The parity data is wrong at LBA <address>-
<address> when scrubbing VD <name>.
WARNING Data recovered
when scrubbing
Data at LBA <address>-<address> has been
recovered when scrubbing VD <name>.
INFO PD freed PD <slot> has been removed from RG <name>.
INFO RG imported Configuration of RG<name> has been imported.
INFO RG restored Configuration of RG <name> has been restored.
INFO VD restored Configuration of VD <name> has been restored.
Snapshot events
Level Type Description
INFO Snapshot deleted The snapshot VD <name> has been deleted.
INFO Snapshot auto
deleted
The oldest snapshot VD <name> has been deleted
to obtain extra snapshot space.
INFO Snapshot taken A snapshot on VD <name> has been taken.
INFO Snapshot space
configured
Set the snapshot space of VD <name> to
<number> MB.
INFO Snapshot rollback
started
Snapshot rollback of VD <name> has been started.
INFO Snapshot rollback
finished
Snapshot rollback of VD <name> has been finished.